Product change notification
The quietest way to lose a customer is to change a part without telling them.
Why we publish this policy
In this industry, most supplier changes are improvements on paper — a cheaper die, a faster line, a new epoxy. They are also the reason a qualified design suddenly fails incoming inspection. Buyers find out months later, after the returns.
We issue written notice before the change ships, not after. The policy below applies to every released part number, regardless of order size.
Notification classes
What gets a PCN, and how much notice.
| Change type | Notice | Samples | Requalification |
|---|---|---|---|
| Die source or die layout | 90 days | Yes, 20 pieces | Usually required |
| Package material or molding compound | 90 days | Yes, 20 pieces | Recommended |
| Marking or date code format | 30 days | Photo only | Not required |
| Reel, tape or packing quantity | 30 days | Yes, 1 reel | Not required |
| Assembly site | 90 days | Yes, 50 pieces | Required |
| Datasheet parameter change | 90 days | Yes | Required |
How to receive notices
Three ways to be on the list.
- Ask your sales contact to register the part numbers you buy — we keep a list per customer, not a mailing list.
- For distribution partners, notices go to the quality contact on the distributor agreement by default.
- If you have not received a notice for a part you buy in volume for more than a year, ask us to confirm the part is unchanged. Silence should be verifiable.
Send the part number and the application.
We will confirm the equivalent, the price at your quantity and the lead time — usually within 48 hours.